Seitenhafenbridge (analysis)

A detailed assessment of the condition of an object.

Properties

Element type
:
Analysis
Summary
:
The monitoring system was included in the tender for the bridge. The tender design was prepared including specifications of sensors. Detail design was already considering the monitoring equipment. The goald was the verification of static calculation or input parameter for further investigations: Comparison of design assumptions with real structure. Calibration of finite element models to real structural behavior. Documentation of construction period or specific loading conditions.
Case type
:
Other
Initiation of assessment
:
Required reliability check (by owner or authorities), Structural deterioration
"Required reliability check (by owner or authorities)" is not in the list (Anticipated change of design working life, Required reliability check, Post event and anticipated damage, Structural deterioration, Pure research interest, Other) of allowed values for the "Initiation of assessment" property.
Predominant verification type
:
Design value criteria
Predominant verification scale
:
Structural system
Structural analysis
:
Ultimate limit state, Serviceability limit state
Information updating
:
Regression
Physical intervention
:
Repair, Strengthening or upgrading
Operational intervention
:
Maintenance, Monitoring

Relations with other elements