Örnsköldsvik bridge (object state)

A condition of an object at a particular time, reflecting the object's ability to fulfil it's requirements.

Properties

Element type
:
Object state
Summary
:
The bridge was tested to failure and was able to take about 6 times the load it was designed for without strengthening and about 8 times with strengthening with Near Surface Mounted Reinforcement (NSMR) of Carbon Fibre Reinforce Polymer (CFRP) Bars.
Performance indicator
:
Load bearing capacity
Inspection method
:
Physical methods

Relations with other elements



The inspection method used in this case study to determine the object state was "Physical methods". This can include any of the following surveying technologies. Click one of the links below for more information:
Physical methods